Seismic design and analysis for a high-rise frame-core tube hybrid structure in Wuxi

Chen Xiaodong,Xiao Zhibin,Xie Yanhua,Huang Zikuang
DOI: https://doi.org/10.19701/j.jzjg.2013.15.002
2013-01-01
Abstract:The height of a high-rise frame-core-wall hybrid structure in Wuxi with 45 stories is 199.80m,which uses steel frame and concrete core wall,and whose height to width ratio of core wall is 9.7.The choice of structural system,results of elastic calculation,analysis for weak floor are presented,and according to the push-over analysis,the seismic performances are discussed.The analytical results show that lateral stiffness of concrete core-wall is very large and the concrete tube bears most of the horizontal force at the elastic stage of this structure.By reasonably reinforcing and increasing the stiffness and bearing capacity of the steel frame,frame-core-wall hybrid structure can form effective dual seismic resistant system which has high seismic performances.