Structure Strenghtening Design with Adding Storey of Beijing International Financial Center

Zhu Keyi,Lou Yu,Ye Lieping
2008-01-01
Abstract:The storey adding and the change of the function result in the axial compression ratio of some frame columns of the built two-storey building exceeding standard limit value.The shear strength of original transition beam cannot meet the code requirements.An exploratory effort is made on the application of carbon fiber to the seismic extension strengthening of the columns,as well as the application of transition beam made of steel fiber reinforced concrete by means of compared calculation and experimental validation.Two technic are successfully adopted in the project of Beijing International Financial Centre.
What problem does this paper attempt to address?