APPLICATION OF PRESTRESSED STEEL STRIPS RETROFITTED METHODS IN AN ADDING STORY BUILDING FOR A SUPERMARKET

Yong Yang,Dawei Chen,Bo Zhang
DOI: https://doi.org/10.13204/j.gyjz201503010
2015-01-01
Abstract:After the extension-story for a market, the axial compression ratio of thirty-one frame columns exceeds the limiting value specified by current concrete structure design code.Based on the study of confined concrete theory, the calculation formula of axial compression ratio of reinforced concrete column strengthening with prestressed steel strip was derived.After calculation by the derived formula, the axial compression ratio of former frame columns exceeding the limiting value could meet the requirements of the current concrete structure design code.
What problem does this paper attempt to address?