Study on the control technology of potassium permanganate pretreatment process in water treatment plant

Lin Pengfei,Zhang Xiaojian,Chen Chao,Zhang Cheqiong
DOI: https://doi.org/10.3969/j.issn.1002-8471.2013.08.005
2013-01-01
Abstract:Using the Taihu Lake raw water as study object,the impacts of the water qualities,the initial concentrations of potassium permanganate,and the pretreatment time on the concentrations of potassium permanganate and total manganese in potassium permanganate pretreatment process effluent were tested.The results showed that if the initial concentration of potassium permanganate was lower than 2 mg/L,the both concentration of potassium permanganate and total manganese were lower than 0.1 mg/L which fitted the requirement of the standards.Otherwise,the colority and the total manganese indexes would exceed the standards.The concentration of CODMn in raw water would influence the up-limit of potassium permanganate dosage significantly.The higher the concentration of CODMn in raw water,the higher up-limit of the potassium permanganate dosage would be.The pretreatment time also had great influence on the effluent concentrations of potassium permanganate.When the pretreatment time was less than 80 minutes,the effluent concentrations of potassium permanganate decreased with the increase of pretreatment time;while when the pretreatment time was more than 80 minutes,there was no obvious improvement of the effluent water quality with the further increase of pretreatment time.
What problem does this paper attempt to address?