Preozonation/Conventional Technology/Ultrafiltration Process for Purification of Taihu Lake Water

Dong-lin ZHU,Cheng SUN
DOI: https://doi.org/10.3969/j.issn.1000-4602.2012.03.010
2012-01-01
Abstract:Eutrophication leads to a lot of problems in drinking water treatment.In order to provide a reference for upgrading waterworks,a pilot study on treatment of Taihu Lake water using the combined process of preozonation,conventional technology and ultrafiltration was carried out,and the ultrafiltration membrane fouling was analyzed.The results showed that the average turbidity,CODMn,UV254 and DOC in the treated water by the combined process were 0.09 NTU,2.23 mg/L,0.039 cm-1 and 2.90 mg/L,and the total removal rates were 97.25%,34.41%,40.48% and 28.55% respectively.The average particles larger than 2 μm in the membrane effluent were 16 p/mL,and neither bacteria nor E.coli was detected.In addition,the combined process could effectively remove iron,manganese and algae in water,and the contents in the treated water were lower than the standard limits.Compared with direct ultrafiltration of raw water,the TMP of the combined process was increased more stably.Therefore,the combined process can be used for micro-polluted lake water treatment.
What problem does this paper attempt to address?