Integrated Coagulation and Ultrafiltration for Purification of Reservoir Water in Southern China

Xihui Zhang
2010-01-01
Abstract:Integrated coagulation and ultrafiltration was used to purify reservoir water in batch lab tests.The tests investigate the pollutants removal efficiencies,the membrane operating characteristics and cleaning methods.The results indicate that the effluent turbidity was less than 0.02 NTU,the oval efficiencies of the chemical oxygen demand(CODMn),dissolved organic carbon(DOC),and UV absorbance at 254 nm(UV254) were improved by 38% on average and that the removal efficiencies of DOM fluorescent substances were better than in the conventional process.The removal efficiencies of natural organic matter(NOM) with molecular weights(MW) of 1 000~2 000 were above 48% while the removal rates of NOM with MW 500~1 000 were about 10%.The removal efficiencies of ammonia nitrogen(NH3-N),nitrate nitrogen(NO-3-N) and total phosphorus(TP) were 19%~29%.The results show that combined alkaline-acid cleaning or alkaline-EDTA cleaning have better cleaning effects.
What problem does this paper attempt to address?