Experiments with Different Combinations of Ultrafiltration Membrane Technological Processes for Biological Stability of Chlorine Disinfection in Drinking Water Treatment

Li Chunmin,Li Xing,Yang Yanling,Guo Dong,Guo Lixia,Xiang Kun,An Dongzi
DOI: https://doi.org/10.3969/j.issn.1009-0177.2012.01.005
2012-01-01
Abstract:Using a reservoir's micro-polluted water as the test water sample,compared the effects between different ultrafiltration combinations process,investigated chlorine disinfection effect on the inactivation of heterotrophic bacteria and continuous disinfection capability,studied residual chlorine decay,the concentration of disinfection by-products and biological stability,comprehensively evaluated the safety of chlorine disinfection about bio-security and chemical safety.The results show,coagulation-powder activated carbon-ultrafiltration has the best effection,which can remove 100 % total bacteria and E.coil.It has strong continued disinfection capability,after 72 h the amount of residual chlorine in water is 0.5 mg / L,the total bacteria and E.coil removal rate is still 100 %,and HPC is less than 100 CFU / mL,meeting drinking water health standards.Its THMs concentration is under 10 μg / L,AOC is lower than 100μgac-C / L,consistent with the requirements of biological stability of chlorination.