Experimental Study on UF&RO Technology in Emergency Drinking Water Treatment
Qingling GUO,Qi BIAN,Shu GAN,Yanchun LI,Xinyang WANG,Yueping YANG
DOI: https://doi.org/10.16796/j.cnki.1000-3770.2018.01.018
2018-01-01
Abstract:Ultrafiltration/reverseosmosis double membrane technology was used in emergency drinking water treatment system to research the removal efficiency of each pollution parameter,and the organic micro-polluted water was used as the raw water,recommended standard of raw water quality was put forward to provide theoretical support for emergency drinking Water treatment by double membrane technology.The test indicated that,typical urban river pollutants included total coliform bacteria,ammonia nitrogen,total nitrogen and some disinfection by-products such as dichloromethane trichloracetic aldehyde and some precursors such as acetaldehyde.Compared to'Hygienic Standard for Drinking Water'(GB5749-2006),UF and RO technology had a lower removal rate on COD,BOD,anionic surfactants and methylene chloride,which was 15%,6.9%,28.6% and 46.7% respectively,the removal rate on petroleum oil was 0%,and other index removal rate was between 80%~99%.This technology should be combined with other water treatment technology for different types of raw water.When raw water was close to neutral,the producing water from reverse osmosis presented slightly acidic,so it needed to add mineralization process for water quality adjustment.According to this removal rate and'Hygienic Standard for Drinking Water',and provided the producing water which treated by double membrane reach the standard,the raw water must met requirement of Environmental Quality Standards for Surface Water'or the content of COD,BOD,anionic surfactants,methylene chloride and petroleum oil not exceeded 23.5 mg/L,4.29 mg/L,0.28 mg/L,0.038 mg/L and 0.005 mg/L respectively.