PERFORMANCE OF PURIFICATION PROCESS IN A WATER TREATMENT PLANT IN SOUTH CHINA

YAO Zhi-wen,DING Xiao-wei,LI Wei-bing,LI De-sheng,YU Lian-qun,WANG Zhan-sheng
DOI: https://doi.org/10.16796/j.cnki.1000-3770.2008.12.025
2008-01-01
Abstract:Micropolluted raw water was treated by pre-O3+ conventional treatment +O3/BAC purification process, which can achieve the desired result.When the respective premises of CODMn, UV254,turbidity and NH3-N in raw water were 4.4~5.9 mg·L-1,0.13~0.17cm-1, 7.9~13.5NTU and 0.07~0.84 mg·L-1, the respective removal rates of CODMn, UV254, turbidity and NH3-N by purification process were 50%,65.6%,96.8%,100%.After the purification process, the CODMn 2.0~2.6 mg·L-1,UV254 0.048 cm-1, turbidity<0.3NTU, NH3-N<0.01 mg·L-1 were reach the Standards for Drinking Water Quality(GB5749-2006) completely.
What problem does this paper attempt to address?