Corrosion and Fouling of Heat Transfer Surfaces

Prabir Basu,Cen Kefa,Louis Jestin
DOI: https://doi.org/10.1007/978-1-4612-1250-8_14
2000-01-01
Abstract: One of the major causes of outage of a modern utility boiler is failure of its boiler tubes. Over the period from 1959 to 1991, boiler tube failures have been ranked as the number one equipment problems in fossil fuel fired power generating plants in the USA. Equivalent unavailability factor owing to tube failure for plants larger than 200 MW capacities was 2.7%. (DOE. 1998). Leading causes of boiler tube failures in the USA arranged in order of availability loss (MWth) are shown below (DOE, 1998): 1.  Corrosion fatigue 2.  Fly ash erosion 3.  Under deposit mechanism (hydrogen damage and acid phosphate corrosion) 4.  Long-term overheating/creep 5.  Short-term overheating 6.  Soot blower erosion 7.  Fireside corrosion of water wall, superheater, and reheater
What problem does this paper attempt to address?