Influence of Water Ring Vacuum Pump Performance on 300 MW Unit Economy

HU Yong,ZHUO Xun-jia,HUANG Jin-tao,LIU Xin-long,JU Lin-cang
DOI: https://doi.org/10.3969/j.issn.1673-1603.2011.04.007
2011-01-01
Abstract:Based on the theory of condensation heat transfer and the state equation of ideal gas,the mathematical model of condenser heat transfer coefficient and pressure is established.The paper obtained the relationship between condenser heat transfer coefficient and working water temperature under different loads and different cooling water temperatures based on the performance curves of water ring vacuum pump.The effects of working water temperature on 300 MW unit economic are analyzed.The study may be utilized to improve condenser vacuum and the stability of water ring vacuum pump performance.
What problem does this paper attempt to address?