Research on the Influence of the Condenser Fault on the Optimization of the Circulating Water System

种道彤,刘继平,严俊杰
DOI: https://doi.org/10.3969/j.issn.1001-5884.2003.06.005
2003-01-01
Abstract:Based on the changed work state theory of the thermal system, a mathematical model is developed to optimize the open circulating water system when the condenser has fault. For an example, a 300MW condensing-unit with two circulating water pumps was calculated. When the coefficient of heat transfer decreases, the simulation shows that the critical load on which the system of two pumps supply water to the condenser is better than the system of one pump is reduced along with the decreases. The optimization of the circulating water system can be directed theoretically and practically by this conclusion.