Finite Element Analysis on the Bearing Capacity for Connection of Sharing on a Shear Load by Friction-Type High-Strength Bolts and Side Welds

WANG Jiao-jiao,SHI Yong-jiu,WANG Yuan-qing,BAI Run-shan,MA Jian-suo
DOI: https://doi.org/10.3969/j.issn.1002-8528.2013.01.004
2013-01-01
Building Science
Abstract:Connection of sharing on a shear load by bolts and welds is proposed by "Technical specification for high strength bolt connections of steel structures,JGJ82-2011".In that kind of connection,both bolt and weld joining are employed in one connection,and resist the same shear force.The finite element method is taken to analyze the mechanical performance of such connection with friction-type high-strength bolts and side welds.Failure mode and component of bearing capacity are discussed through several finite element numerical examples of different bolts-to-welds strength ratio.Hence the calculated formula is gotten for bearing capacity of combined connection.And parametric analysis of weld size and bolt specification is also made.The result shows that when the bolts-to-weld strength ratio is 0.85,both of bolts strength and welds strength are displayed almost completely.While the ratio is not 0.85,there exist different extents of waste for the higher strength.The formula of bearing capacity could be expressed as a linear combination of bolts and welds shear strength.As a result,the co-use of bolts and weld in one joint is an efficient way of structural reinforcement or modification.
What problem does this paper attempt to address?