FINITE ELEMENT ANALYSIS OF THE LOADING CAPACITY OF CO-USE OF WELD AND BOLTS JOINT FOR REINFORCEMENT

Wang Yuanqing,Yang Wen,Shi Yongjiu
DOI: https://doi.org/10.3969/j.issn.1007-9963.2006.04.007
2006-01-01
Steel Construction
Abstract:The co-use of weld and bolts joint has been proposed in “The Specification of High-Strength Bolt Connection in Steel Structures”(JGJ 82,consultative draft). Both bolt and weld joining are employed in this form of joint in one connection,and resist the same shear force. By this means,the shear strength of the joint will be enhanced greatly. It is very suitable for those cases where the design of the bolts bearing capacity is not sufficient or where the applied loads increase. Therefore,the co-use of weld and bolts joint is an efficient way of structural reinforcement or modification. Finite element analysis is employed,and different details and geometrical parameters of the weld are discussed.Finally,the results of finite element analysis are compared with the proposed formula in the consultative draft,and suggestions are provided.
What problem does this paper attempt to address?