Abstract:ABSTRACT:The existing friction-type high-strength bolted joints may occur under-load or damage under certain shear forces.In this case,the joints can be reinforced by weld reinforcement.In the paper,through the experimental study,the bearing capacity and variation regularity of the pure bolted specimens were analyzed in both cases:the pure bolted specimens were reinforced with the same weld reinforcement at different levels of damage and with different weld seams at the same level of damage.The influence of the construction sequence on the connection reinforcement effect was also analyzed.It could provide a reference for the design of the existing steel structure joint reinforcement project.