Study on Shear Capacity of High-strength Bolted Bearing-type Joint

Qi Ouyang
2013-01-01
Abstract:The friction forces between connecting plates are not taken into account in the shear capacity calculation of high-strength bolted bearing-type joints in the current Codes,which is not consistent with the bearing mechanism of high strength bolts.The principle of virtual work was adopted to go through pre-stress simulation method,and the finite element method was adopted to analyze the loading process of bearing-type joints.The results show that,without considering the friction forces between connecting plates,when the bearing capacity of connection is controlled by bolt strength,the shear capacity of high-strength bolted bearing-type joints will be underestimated.In this paper,based on numerical simulation,a reasonable method considering friction forces between connecting plates was proposed to calculate shear capacity of high-strength bolted bearing-type joints.Compared with FEM results,the error of new method is less than 10%.
What problem does this paper attempt to address?