Slice emittance measurement for photocathode RF gun with solenoid scanning and RF deflecting cavity

Chen Li,WenHui Huang,YingChao Du,LiXin Yan,ChuanXiang Tang
DOI: https://doi.org/10.1007/s11433-011-4557-9
2011-01-01
Abstract:The radiation of high-gain short-wavelength free-electron laser depends on the slice transverse emittance of the electron bunch. This essay introduces the method of slice emittance measurement, and shows the brief setup of this experiment using the solenoid scanning and RF deflecting cavity at Tsinghua University. The preliminary experimental results show that the slice rms emittance of the electron bunch generated by photocathode RF gun has considerable variations along the bunch and is typically less than 0.55 mm mrad for the laser rms radius of 0.4 mm.