Rf Deflecting Cavity Design For Bunch Length Measurement Of Photoinjector At Tsinghua University
SHI Jia-Ru,CHEN Huai-Bi,TANG Chuan-Xiang,HUANG Wen-Hui,DU Ying-Chao,ZHENG Shu-Xin,Li Ren,施嘉儒,陈怀璧,唐传祥,黄文会,杜应超,郑曙昕,任丽
DOI: https://doi.org/10.1088/1674-1137/32/10/014
IF: 2.944
2008-01-01
Chinese Physics C
Abstract:RF deflecting cavity can be used for bunch length measurement and is designed to diagnose the beam produced by the photocathode electron gun which was built at Tsinghua University for the Thomson scattering experiment. Detailed discussion and calculation for measuring the 3.5 MeV bunch and another with Further acceleration to 50 MeV, which is under development, are presented. A standing-wave deflecting cavity working at 2856 MHz is designed and the power feeding system has been planned.