A C-band Deflecting Cavity Design for High-precision Bunch Length Measurement
Xiaopeng Jiang,Huaibi Chen,Jiaru Shi,Píng Wang
DOI: https://doi.org/10.18429/jacow-ipac2015-wepmn014
2015-01-01
Abstract:A standing wave RF deflecting structure has been designed as a tool for high-precision bunch length measurement. This 3-cell deflecting cavity is designed to operate at a frequency of 5.712GHz. In this paper, the RF design and thermal analysis of the deflecting cavity are introduced. We study the electromagnetic field distribution inside the cavity. The coupler design is also discussed. And the beam dynamics simulation is shown. INTRODUCTION RF deflecting cavities have been widely used in the characterization of the longitudinal and transverse phase space in ultra-short electron beams [1]. Recently an ultrafast electron source with femtosecond-level is used for diffraction and imaging system [2]. The main parameters of the bunch are given below (Table 1). A Cband deflecting cavity is designed for high-precision measurement of the bunch length. Table 1: Beam Parameters Parameters Value Electron beam energy (MeV) 2 Transverse beam size (mm) 0.5 Longitudinal beam size(fs) 20 In the second section of the paper, the design of the deflector is discussed including the structure design, electromagnetic field characterization, beam dynamics and the coupler design. Thermal simulation calculated by CST is shown in the third part. RF DEFLECTOR DESIGN The required transverse deflecting voltage VT=1MV can be, achieved by both traveling wave (TW) and standing wave (SW) structures [1]. In our case, we choose a 3-cell SW structure operated at a frequency of 5.712GHz. The 3D-model draw by CST is shown in Figure 1. Model Design The main part of the model is composed of several cylinders. The radius of the cell is determined by both the frequency and flatness of the magnet field [3]. The working mode is TM110 mode and π-mode. Length of the middle cell is given by [3]: 0 2 c l . (1) where λ and ω0 are the wavelength and angular frequency of the microwave, c is the speed of light, l is the length of the middle cell which include half of the gap between middle cell and end cell each side. Meanwhile, the length of the end cell is determined by beam dynamics which is discussed later in this paper. In order to make sure the polarization direction not changed while two cell coupled, two end cells are slotted on the edges which are perpendicular to the direction we put the coupler. According to the discussion above, the dimensions of the cavity is shown in table 2. Table 2: Dimensions of the RF Cavity Dimensions Value(mm) Radius of middle cell 30.85 Length of middle cell 21.49 Radius of end cells 30.61 Length of end cells 10.93 Gap between cells 4.76 Radius of beam pipe 8 Radius of slots 3.5 Figure 1: 3D-design of the deflector. ___________________________________________ *Work supported by NSFC 11375098 and 11327902 #jxp14@mails.tsinghua.edu.cn 6th International Particle Accelerator Conference IPAC2015, Richmond, VA, USA JACoW Publishing ISBN: 978-3-95450-168-7 doi:10.18429/JACoW-IPAC2015-WEPMN014 WEPMN014 2948 Co nt en tf ro m th is w or k m ay be us ed un de rt he te rm so ft he CC BY 3. 0 lic en ce (© 20 15 ). A ny di str ib ut io n of th is w or k m us tm ai nt ai n at tri bu tio n to th e au th or (s ), tit le of th e w or k, pu bl ish er ,a nd D O I. 7: Accelerator Technology T06 Room Temperature RF After the shape is decided, it’s easy to get the cavity parameters such as the transverse shunt impedance. And table 3 shows the main parameters of the RF cavity. With 1 MW input power, the deflecting voltage can be 1.19 MV. Table 3: Cavity Parameters Parameters Value Q0 9003.25 RT/Q(MΩ) 21.49 RT(MΩ) 1.42 P(MW) 1 Vd(MV) 1.19 The deflecting cavity consists of three cell which results in three different mode: 0-mode, π/2-mode and πmode. Because of the symmetrical structure, there will also be three degenerate modes existed. The π-mode we need is given in Figure 2. Frequencies of modes near 5.712GHz is shown in Table 4. Figure 2: π-mode needed in the RF cavity. Table 4: Frequencies of Different Modes Modes Frequency(GHz) π-mode 5.7121 π/2-mode 5.7518 0-mode 5.8413 Degenerate π-mode 5.6982 Electromagnetic Characterization The cavity is working in TM110 mode and in this mode, the x-component of the electric field is much smaller than the y-component meanwhile the y-component of the magnet field is much smaller than the x-component. As a result, particles crossing the cavity will only kicked in y direction, mainly influenced by the magnet field. The flatness of magnet field has been adjusted to around 0.995. The normalized Ey and Hx along axis z are shown in Figure 3 and Figure 4 respectively. Figure 3: Normalized Ey along z axis. Figure 4: Normalized Hx along z axis. Beam Dynamics Figure 5 and Figure 6 gives out the result of beam dynamics simulation. The parameters of the electron source is shown in Table 5. Table 5: Parameters of Electron Source Parameters Value Number of micro particles 1311 Energy(MeV) 2 Current(A) 0.02 Distribution in x-y plane Round Transverse beam size (mm) 0.5 The particles at zero-phase have zero deflection and a little vertical offset. The precise value of vertical offset is 0.0575mm. The phase of the electromagnetic field is changed from -4 degree to 4 degree by step of 2 degrees in simulation. The change of phase can be translated into the longitudinal offset of beams as below: 0 2 2 p c p z . (2) where Δp means the change of phase, Δz is longitudinal offset. From Figure 5 and Figure 6, we know that the vertical offset and deflection is proportional to phase shift, which means we can get the bunch length by measuring vertical bunch size after the exit of the cavity. -100 -50 0 50 100 -1 -0.5 0 0.5 1 Z Axis(mm) N or m al iz ed E y -100 -50 0 50 100 -1 -0.5 0 0.5 1 Z Axis/mm N or m al iz ed H x 6th International Particle Accelerator Conference IPAC2015, Richmond, VA, USA JACoW Publishing ISBN: 978-3-95450-168-7 doi:10.18429/JACoW-IPAC2015-WEPMN014 7: Accelerator Technology T06 Room Temperature RF WEPMN014 2949 Co nt en tf ro m th is w or k m ay be us ed un de rt he te rm so ft he CC BY 3. 0 lic en ce (© 20 15 ). A ny di str ib ut io n of th is w or k m us tm ai nt ai n at tri bu tio n to th e au th or (s ), tit le of th e w or k, pu bl ish er ,a nd D O I.