Environmental Chemistry
Abstract:Fenton reagent was used for the further treatment to the effluent of bio-polluted wastewater which had been pretreated by coagulation and sedimentation to solve the biological pollution problem resulted from the rapid development of modern biotechnology.According to the orthogonal experiment and single factor experiments,the effects of four factors with four levels:dosage of H2O2,pH value,reaction time and the mole ratio of H2O2 over Fe2+(H2O2/Fe2+)on the organic pollutants removal of bio-polluted wastewater were investigated and optimum operation conditions were proposed.The results showed that the dosage of H2O2 had a greater effect on the organic pollutants removal compared to other three factors.The effect ability ranked the dosage of H2O2> pH> reaction time > H2O2/Fe2+.The optimum operation conditions were 0.088mol·l-1 of H2O2,pH 3.5,4h of reaction time,20∶1 of H2O2/Fe2+.After the wastewater was treated by Fenton reagent under the optimum operation conditions,the total number of bacterium and adenosine-triphosphate(ATP)in effluent could not be detected and relative inhibition light ratio was only 10%.The biological safety including hygienics and environment of the effluent was ensured.In addition,COD in effluent was less than 76mg·l-1as well as the average of ammonia nitrogen,total nitrogen,and total phosphorus were 1.10mg·l-1,2.92mg·l-1,and 0.002mg·l-1 respectively.The effluent quality met the requirement of The First Grade B of"Discharge Standards for Municipal Wastewater Treatment Plant".