Abstract:Fe-C inner electrolytic process together with Fenton oxidation was extensive studied in treating nitrobenzene pharmaceutical wastewater.pH,reaction time,Fe/C ratio and additional amount of H2O2 were investigated by experiment to determine the optimal condition of reaction,then dynamics model was put out according to the test results.According to the test results,it was found that COD removal and nitrobenzene removal could be 43%~48% and 85%~90% respectively,improving 40% ~ 60% than conventional method.In this process,disadvantage of electrode passivation could be lessened and operating stability could be improved.