Abstract:Nitrobenzene wastewater was treated by a three-dimension electrode method coupling electro-Fenton,and the factors affecting the organic matter degradation as well as the treatment efficiency were investigated.The results were then compared with those of the three-dimension electrode method and the common electrode-Fenton method.It is found that(1) with the increase in electrolysis time,initial pH value,polar distance,cell voltage,Fe2+ do-sage and aeration rate,both the chemical oxygen demand(COD) and the nitrobenzene removal first increase and then decrease or change slightly;(2) the optimal conditions for the wastewater treatment are found to be: an electrolysis duration of 2.0h,and initial pH value of 3.0,a polar distance of 6cm,a cell voltage of 30V,a Fe2+do-sage of 1.0g/L and an aeration rate of 0.8m3/h;and(3) in the optimal conditions,the removals of COD and nitrobenzene reach 93.1% and 96.5%,respectively.In addition,according to the GC-MS results of the interme-diate products,the degradation mechanism of nitrobenzene is explored and the superiority of the method over the three-dimension electrode method and the common electrode-Fenton method in terms of nitrobenzene removed is validated.