Methods for Treating Strong Chelate-Containing Wastewater PartⅡ——Chelation/precipitation Process for the Treatment of Mixed Electroplating Wastewater

FANG Jing-li
DOI: https://doi.org/10.3969/j.issn.1004-227x.2007.10.013
2007-01-01
Abstract:The performances of liquid chelating resin DTCR treatment method and alkaline precipitation method were compared. The process flow of DTCR method for the treatment of mixed electroplating wastewater mainly comprises (1) pH adjustment,(2) addition of 1%-2% (mass fraction) DTCR,(3) addition of flocculating agent,(4) agitation,and (5) filtration. The use of NaHSO3 is recommended to reduce Cr(VI) to Cr(Ⅲ) before the addition of DTCR for the treatment of Cr(VI)-containing wastewater. The amounts of DTCR for treating different heavy metal ions were presented. An electroplating wastewater containing 40 g/L Cu2+,28 g/L Ni2+ and 26 g/L Zn2+ was treated with DTCR. The effluent contains 0.5 mg/L heavy metals,meeting the national discharge standard.