Treatment of Electroplating Wastewater by Electrocoagulation

王海东,陈发源,杨春风,赵旭,刘会娟,曲久辉
2013-01-01
Abstract:Treatment of an acid electroplating wastewater was performed by an electrocoagulation process firstly. Effect of current density and treatment time on the removal of total cyanide, heavy metals and COD was investigated. The results showed that total cyanide and heavy metals can be efficiently removed by the electrocoagulation process, which increased with the current density. At a current density of 10 mA/cm2, the residual total cyanide, Cu2+, Ni2+, Cr6+ and Zn2+ were 23.0, 25.0, 4.5, 0.2 and 0.2 mg/L, respectively. Removal of COD by electrocoagulation process was limited. With addition of H2O2 to electrochemical system, the removal efficiency of the total cyanide and heavy metal and COD increased. With a H2O2 dose of 3 mL/L, the residual total cyanide, Cu2+, Ni2+, Cr6+, Zn2+ and COD were 0.2, 2.0, 3.0, 1.5, 0.1 and 220 mg/L, respectively.