Study on treatment of wastewater from electroplating of electronic products by flocculation in combination of decolorization and adsorption

KONG Sifang,ZHOU Xingfeng,OUYANG Fan,CHENG Xueqin,TANG Jun,LIN Jing
DOI: https://doi.org/10.19289/j.1004-227x.2023.23.010
2023-01-01
Abstract:The electroplating wastewater discharged from electronics manufacturing is complicated and hard to be treated,which is one of the key factors restricting the sustainable development of the electronics industry.A two-step flocculation method in combination of decolorization and adsorption was adopted to purify the electroplating wastewater from an electronics manufacturer in Shenzhen.The factors affecting the decolorization and adsorption effectiveness were studied.The optimized conditions are flocculant CY-08 8‰ by weight,pH 11,temperature 55 °C,and time 30 min for decolorization,and flocculant BWG-102 5‰ by weight,pH 6,temperature 35 °C,and time 25 min for adsorption.After decolorization followed by adsorption under the said conditions,the concentrations of chemical oxygen demand(COD),total phosphorus,ammoniacal nitrogen,and heavy metal ions including chromium,iron,zinc,nickel,and copper in effluent meet the demands of the Table 2 of national emission standard GB 21900-2008 and the Table 1 of the Guangdong Province's emission standard DB 44/1597-2015.
What problem does this paper attempt to address?