Study on Thermal Sensitivity Characteristics of Vertical Membrane Water Wall in Supercritical Pressure W Shaped Flame Boiler

WANG Wei-shu,ZHU Xiao-jing,BI Qin-cheng,YANG Dong,HUANG Jin-tao,WU Gang
DOI: https://doi.org/10.13334/j.0258-8013.pcsee.2010.20.010
2010-01-01
Abstract:Thermal sensitivity study was done for 6-head internally ribbed vertical upward membrane water wall of 600 MW supercritical pressure W shaped flame boiler at low mass velocity when heat disturbance occurred.The characteristics of flow sensitivity quotiety and outlet enthalpy sensitivity quotiety were investigated at different heat flux,pressure or mass velocity.Factors which have influence on heat sensitivity of water wall were analyzed in detail.Deviation of flow,enthalpy and temperature of deviation tube were also calculated at different load of W shaped flame boiler separately.The results show that increasing of heat flux leads to an increase in flow sensitivity quotiety and a decrease in outlet enthalpy sensitivity quoiety,and enhances the selfcompensating characteristic of water wall.Increasing of mass velocity decreases flow sensitivity quotiety,and the water wall appears a minus mass flow characteristic when mass flow exceeds a certain value.The hydrodynamics stability of water wall is enhanced by rising pressure.The flow sensitivity quotiety decreases with an increase of steam quality,while the outlet enthalpy sensitivity quotiety increases.The results provide some instructive advice and it is helpful for the safe operation of 600 MW supercritical pressure W shaped flame boiler.