Effects of the gas/particle flow and combustion characteristics on water-wall temperature and energy conversion in a supercritical down-fired boiler at different secondary-air distributions
Xiaoguang Li,Lingyan Zeng,Ning Zhang,Xin Zhang,Minhang Song,Zhichao Chen,Zhengqi Li
DOI: https://doi.org/10.1016/j.energy.2021.121983
IF: 9
2022-01-01
Energy
Abstract:To alleviate the over-temperature of water-wall and increase the energy conversion efficiency of supercritical down-fired boilers, cold-model air/particle flow experiments and in-situ trials were performed to investigate the effects of the secondary-air distribution wall-side deflection coefficient (w s) on air/particle flow and combustion characteristics. As w s increased from 0 to 0.33, the amount of air/particle flow diffused toward water-wall and the corresponding particle concentration both decreased, while the velocity decay was accelerated. At a w s of 0.16, due to prior ignition of fuel-rich flow and a longer flame stroke in lower furnace, the carbon in fly ash and slag were lowest. As w s increased, the thermal load was gradually focused at the furnace center, and the maximum value and deviation of water-wall temperature in lower furnace decreased. Consequently, the temperatures of superheated and reheated steam respectively increased from 542.7 °C to 543.9 °C–560.2 °C and 560.1 °C, respectively. Furthermore, increasing w s from 0 to 0.28 decreased the specific coal consumption from 346.29 to 341.09 g (kW h)−1, indicating the energy conversion efficiency was improved. However, adjusting w s had only a minimal effect on NO x emissions. A w s of 0.28 is recommended to optimize the water-wall temperature, pulverized-coal burnout, and economic performance.
energy & fuels,thermodynamics