The Temperature Characteristics Study of Spiral Water-wall in 350 MW Supercritical Pressure Boilers

Bi Qincheng
2013-01-01
Abstract:In view of the temperature characteristics of water wall in 350MW supercritical pressure boiler of Linzhou thermal power plant,the temperature fields of rectangular fins water wall were numerically studied by the finite volume method,and the spiral membrane water-wall temperature in the lower furnace was analyzed.According to the calculation results,temperature of spiral water-walls increases with the increase of the height of furnace.The highest temperature,which occurs at the facing flame outer of water wall tube or the fin's end,is less than 440 ℃ and does not exceed the permitted value of the metal.Both the highest temperature and the maximum temperature difference increase with increasing the furnace load.As the thermal deviation can be effectively reduced by using spiral water-wall,the temperature of water-walls and the temperature difference of working medium between each tube are very small along the width direction of the furnace.
What problem does this paper attempt to address?