Analysis on the Influencing Factor of Stable Flat Measuring Method for Thermal Conductivity Measurement

孟祥睿,陈晓娟,张如波,魏新利
DOI: https://doi.org/10.3969/j.issn.1000-0712.2008.12.012
2008-01-01
Abstract:The main factors that affect the veracity of steady-state method measuring thermal conductivity are heat resource temperature,ambient temperature,sample thickness and sample thermal conductivity.The cooling rate of cooling plate is different on upper surface and below surface is another important factor.The natural convec- tion empirical formula is used to improve the data processing,the effect of elimination of heat from the side of sam- ple is reduced.It is important to design the experiment to keep the temperature of cooling plate in an appropriate range,and the cooling rate of cooling plate is uniform anywhere at such temperature.
What problem does this paper attempt to address?