Influence of Side Radiating on Thermal Conductivity Measurement

孟祥睿,张如波,陈晓娟,魏新利
DOI: https://doi.org/10.3969/j.issn.1005-9954.2009.03.012
2009-01-01
Chemical engineering
Abstract:The measurement of thermal conductivity is an important item in exploiting high-thermal conductivity adsorbent,and the steady-state method is widely used in measuring thermal conductivity for its brief operation.The elimination of heat from the side of sample is an important influence factor which is discovered by numerical simulation and certified by experiment.The natural convection empirical formula was used to improve the data processing,and a better result was obtained in succeeding experiment by using the improved formula.The simulation and experiment results show that ambient temperature,heat source temperature,thickness of the sample and thermal conductivity of test sample are the main factors that impact the elimination of heat from the side of sample.The temperature difference of heat transfer,the elimination of heat from the side of sample,and its percentage in total heat transfer increase with the decreasing of ambient temperature,the increasing of heat source temperature or thickness of the sample,or the decreasing of thermal conductivity of test sample accordingly.
What problem does this paper attempt to address?