Failure analysis methods and procedures for Stirling cryocooler

Yang Shaohua,Zhang Xiaoming,Liu Xinguang,Wu Yinong
DOI: https://doi.org/10.3969/j.issn.1001-7100.2008.07.001
2008-01-01
Abstract:The main failure modes,failure mechanisms,indication parameters and inspection methods of "Oxford" type Stirling cryocooler were analyzed.Meanwhile,failure analysis methods and procedures for Stirling cryocooler were investigated,and will be used in a 80K/2W sample after accelerated life test.It would support the validation of failure modes and failure mechanisms.
What problem does this paper attempt to address?