Scroll Compressor Vibration Testing and Structural Optimization

YANG Meng,WANG Guo-feng,XU Xin-xi,ZHANG Lu
DOI: https://doi.org/10.3969/j.issn.1006-1335.2013.03.011
2013-01-01
Abstract:Vibration test of a certain type of scroll compressor was conducted. The high-frequency vibration spectrum of the major components of the compressor was derived. Modal analysis of the scroll compressor was carried out through the finite element analysis software ANSYS and the first six natural frequencies were obtained. Comparing the results of vibration spectrum analysis with those from the test, it was found that resonance occurs on the upper shell, and junction of the shell and the housing is prone to appear fatigue damage. Three improvement schemes, increasing the thickness of the upper shell, increasing the radian of the upper shell and increasing the thickness of the shell at the junction, were put forward. These schemes were verified through the finite element analysis by ANSYS. Comparison of the results shows that among these schemes the latter two schemes were effective for vibration reduction of the compressor.
What problem does this paper attempt to address?