A method of measuring dielectric loss of current transformer by changing frequency

WANG Xiao-tang,LI Xiao-qian,JIN Gui,TANG Chao-ying
2010-01-01
Abstract:According to the feature that the measurement of dielectric loss of the current transformer is easily interfered by electric and magnetic field, h igh-voltage and frequency-changing experiments are operated on the basis of regular experiments.High-voltage experiments and frequency-changing experiments both can effectively exclude interference of electric and magnetic field, thus getting a reliable result of dielectric loss. Via comparison ,h igh-voltage experiments must work under relatively high voltage and are difficult to operate.However,frequency-changing experiments can get stable dielectric loss statistics under voltage much lower, while they are easy to operate . As a consequence, the method of measuring dielectric loss by changing frequency is of more superiority and suitable to be promoted widely.
What problem does this paper attempt to address?