A CMOS-MEMS accelerometer with tri-axis sensing electrodes arrays

Ming-Han Tsai,Yu-Chia Liu,Chih-Ming Sun,Chuanwei Wang,Weileun Fang
DOI: https://doi.org/10.1016/j.proeng.2010.09.298
2010-01-01
Procedia Engineering
Abstract:This study presents a single proof-mass CMOS-MEMS accelerometer with integrated tri-axis sensing electrodes arrays. The in-plane finger-type and out-of-plane plate-type gap-closing sensing electrodes are employed in this study. The standard TSMC 0.35 mu m 2P4M CMOS process and in-house post-CMOS process was used to implement the device. The capacitive in-plane and out-of-plane sensing gap can be defined by the minimum line-width and the thickness of CMOS process. The structure size is only 500x500 m(2). Measurement results show the sensitivities (non-linearities) are 2.47mV/g (1.3%) in X-axis, 2.87mV/g (1.4%) in Y-axis, and 3.89mV/g (3.4%) in Z-axis. The noise flow for in-plane and out-of-plane sensing are 0.59mg/rtHz and 0.8mg/rtHz. (C) 2010 Published by Elsevier Ltd.
What problem does this paper attempt to address?