Influence of Hydrophobicity on Composite Insulator's Flashover Voltage Under Light Ice Accumulation Conditions

Cui W,Su H,Li J,Wang D,Sun Z,Jia Z.
DOI: https://doi.org/10.3969/j.issn.1003-6520.2012.10.019
2012-01-01
Abstract:The icing flashover accident occurs on the composite insulator strings under light ice accumulation conditions.The performance of insulators deteriorates under light ice accumulation and wet contamination deposition conditions.In order to deeply investigate the impact of hydrophobicity on ice flashover performance,experiments of full-size composite insulators were carried out in artificial climate chamber using rise-voltage method.In our tests,the icing flashover voltage of composite insulator with good hydrophobicity was quite high,while icing flashover voltage of the composite insulator without hydrophobicity was lower than the contamination flashover voltage when they were both pre-contaminated with the same equivalent salt deposit density(ESDD).Hydrophobicity of composite insulators plays an important role in preventing the occurrence of flashover accident under light ice accumulation and wet contamination deposition conditions.Flashover under light icing conditions can be considered as one kind of pollution flashover and partial arcs are always developed along the surface of shed,thus increase creepage distance while keep the structure height constant is an effective way to prevent flashover in light icing condition.
What problem does this paper attempt to address?