Why would you put a flashlight in a dark matter detector?

R. Gibbons,H. Chen,S.J. Haselschwardt,Q. Xia,P. Sorensen
DOI: https://doi.org/10.1088/1748-0221/19/01/p01013
2024-01-17
Journal of Instrumentation
Abstract:Silicon photomultipliers (SiPMs) are solid-state, single-photon sensitive, pixelated sensors whose usage for scintillation detection has rapidly increased over the past decade. It is known that the avalanche process within the device, which renders a single photon detectable, can also generate secondary photons which may be detected by a separate device. This effect, known as external crosstalk, could potentially degrade the science goals of future xenon dark matter experiments. In this article, we measure the effect of external crosstalk in a dual-phase, liquid xenon time projection chamber fully instrumented with SiPMs. We then consider the implications for a future xenon dark matter experiment utilizing SiPMs and discuss possible solutions.
instruments & instrumentation
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the signal contamination problem caused by external crosstalk when using silicon photomultipliers (SiPMs) in dark matter detectors. Specifically, when an SiPM detects a single photon, an avalanche process will be triggered, and the secondary photons generated during this process may be detected by other SiPMs, forming additional and unexpected signals. This external crosstalk effect is particularly significant in multi - phase liquid xenon time - projection chambers (TPCs) and may affect the scientific goals of future xenon dark matter experiments, especially reducing the signal detection accuracy at low - energy thresholds. To quantify this effect, the authors conducted experiments in a two - phase liquid xenon TPC equipped with two SiPM arrays at the top and bottom. By comparing the signal differences detected by the top SiPM array when the bottom SiPM array was on and off, the researchers measured the probability of external crosstalk and discussed its impact on future xenon dark matter experiments and possible solutions. The key points of the paper include: - **Problem Definition**: The impact of external crosstalk on the performance of dark matter detectors, especially at low - energy thresholds. - **Experimental Design**: Use a two - phase liquid xenon TPC equipped with two SiPM arrays at the top and bottom, and quantify external crosstalk by comparing signals under different conditions. - **Results and Analysis**: The measurement results show that under the experimental conditions, the probability of a single detected photon generating external crosstalk can reach about 5%, and this probability increases with the overvoltage. - **Future Prospects**: Several strategies for reducing external crosstalk are proposed, such as using optical infrared filters or adopting a hybrid light detector setup (using SiPM at the top and PMT at the bottom). In summary, this study aims to reveal the external crosstalk problem of SiPM in dark matter detectors through experimental data and theoretical analysis, and provide guidance for future experimental designs.