SBC-SNOLAB scintillation system and SiPM implementation for dark matter searches

H. Hawley-Herrera,the SBC collaboration
DOI: https://doi.org/10.1088/1748-0221/19/01/c01023
2024-01-20
Journal of Instrumentation
Abstract:The Scintillating Bubble Chamber (SBC) collaboration is constructing a 10 kg liquid argon (LAr) bubble chamber at SNOLAB called SBC-SNOLAB having the main objective of detecting dark matter. One of the most novel aspects of SBC-SNOLAB is the scintillation system, consisting of LAr doped with on the order of 10 ppm Xe, 48 FBK VUV silicon photomultipliers (SiPMs), the SiPM electronics, two quartz jars, and liquid CF 4 used as an hydraulic fluid and additional source of scintillation photons. In contrast with traditional single or dual phase scintillation experiments, the collected LAr scitillation light is used to veto signals which involve the detection of at least a single photoelectron. These proceedings will describe in detail the current SBC-SNOLAB scintillation system which includes the unique design considerations for SBC-SNOLAB that limit the light collection efficiency and the electronics.
instruments & instrumentation
What problem does this paper attempt to address?
This paper aims to explore and implement the SBC - SNOLAB scintillation system for dark matter detection and the application of its silicon photomultiplier (SiPM). Specifically, the paper mainly addresses the following aspects: 1. **Improving the sensitivity of dark matter detection**: The goal of the SBC - SNOLAB project is to use liquid argon (LAr) bubble chamber technology, combined with a scintillator as an active fluid, to improve the sensitivity of detecting low - mass dark matter. By doping a small amount of xenon (Xe) in LAr, the generation of scintillation light can be enhanced, thereby improving the detection efficiency of the signal. 2. **Suppression of background events**: The paper describes in detail the unique design of the SBC - SNOLAB scintillation system, especially how to use scintillation light to mark and suppress background events. This includes using 48 FBK vacuum ultraviolet (VUV) SiPMs to collect LAr scintillation light and 16 SiPMs to collect the scintillation light of liquid CF4. These measures help to reduce background noise and improve the purity of the signal. 3. **Detector design in a low - background environment**: Since SBC - SNOLAB is a low - background detector, special considerations are required in material selection and design. The paper discusses how to select low - radioactivity materials and keep components that may generate radioactivity away from the core area of the detector to reduce background interference. 4. **Optimization of light collection efficiency**: Although high light collection efficiency is important for energy reconstruction, the main goal of SBC - SNOLAB is to use the collected photons as a veto means for background events. Therefore, the paper discusses how to optimize the light collection efficiency under engineering constraints, especially in the case of multiple optical interfaces and low - background requirements. 5. **Characterization and optimization of SiPM performance**: The paper also introduces the characterization work of SiPMs by the SBC collaboration group, including measuring their gain, breakdown voltage, dark noise rate, and the probability of related avalanches. These studies help to optimize the performance of SiPMs and improve the signal - to - noise ratio. In summary, the main problems addressed in this paper are how to design and implement an efficient scintillation system to improve the sensitivity of dark matter detection and the ability to suppress background events.