Capacitive coupling study of the HERD SCD prototype: preliminary results

Ruo-Si Lu,Rui Qiao,Ke Gong,Wen-Xi Peng,Wei-Shuai Zhang,Dong-Ya Guo,Jia-Ju Wei,Yi-Ming Hu,Jian-Hua Guo,Qi Wu,Peng Hu,Xuan Liu,Bing Lu,Yi-Rong Zhang
2024-02-27
Abstract:The Silicon Charge Detector (SCD) is a subdetector of the High Energy Cosmic Radiation Detection payload. The dynamic range of the silicon microstrip detector can be extended by the capacitive coupling effect, which is related to the interstrip capacitance and the coupling capacitance. A detector prototype with several sets of parameters was designed and tested in the ion beams at the CERN Super Proton Synchrotron. The capacitive coupling fractions with readout strip and floating strip incidences were studied using the beam test data and SPICE simulation.
Instrumentation and Detectors,Nuclear Experiment
What problem does this paper attempt to address?