Atmospheric dispersion corrector for a multi-object spectroscopic mode of HROS-TMT

Manjunath Bestha,Amirul Hasan,Devika Divakar,Arun Surya,S. Sriram,T. Sivarani,Ajin Prakash,Parvathy M,Sudharsan Yadav
DOI: https://doi.org/10.1117/12.2677192
2023-10-24
Abstract:Highly multiplexed spectroscopic surveys have changed the astronomy landscape in recent years. However, these surveys are limited to low and medium spectral resolution. High spectral resolution spectroscopy is often photon starved and will benefit from a large telescope aperture. Multiplexed high-resolution surveys require a wide field of view and a large aperture for a suitable large number of bright targets. This requirement introduces several practical difficulties, especially for large telescopes, such as the future ELTs. Some of the challenges are the need for a wide field atmospheric dispersion corrector and to deal with the curved non-telecentric focal plane. Here, we present a concept of Multi-Object Spectroscopy (MOS) mode for TMT High-Resolution Optical Spectrograph (HROS), we have designed an atmospheric dispersion corrector for individual objects that fit inside a fiber positioner. We present the ZEMAX design and the performance of the atmospheric dispersion corrector for all elevations accessible by TMT.
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: in large telescopes (such as the future Thirty - Meter Telescope, TMT), how to effectively correct atmospheric dispersion to achieve high - resolution multi - object spectroscopic observations. ### Problem Background 1. **Influence of Atmospheric Dispersion** - Ground - based telescopes are affected by the refraction of light of different wavelengths in the Earth's atmosphere, causing light of different wavelengths to be deflected to different degrees. This effect is particularly significant on large - aperture telescopes because they have a larger field of view and higher resolution. - Atmospheric dispersion will reduce the image quality, especially at low zenith angles (that is, when the telescope is pointed close to the horizon), which will cause the light signal received by the spectrometer to weaken, thus affecting the observation effect. 2. **Requirements for Multi - object Spectroscopic Observations** - High - resolution spectroscopic observations usually require a large number of photons, and large - aperture telescopes can provide more photon - collecting capabilities. - Multi - Object Spectrometers (MOS) can observe multiple targets simultaneously in one observation, but this also means that accurate atmospheric dispersion correction needs to be carried out in a wide field of view. ### Solution To solve the above problems, the author designed an **Atmospheric Dispersion Corrector (ADC)** specifically for the multi - object spectroscopic mode (MOS), which specifically includes the following points: 1. **RADC Design** - Use a Rotary Atmospheric Dispersion Corrector (RADC), which consists of two Amici prisms rotating in opposite directions and can correct dispersion and deviation simultaneously. - The design of the RADC makes the light beam not deviate from the original direction, which is crucial for maintaining the stability of the fiber input end and avoiding signal loss. 2. **Optical Design and Performance Evaluation** - Detailed optical design and performance evaluation were carried out using ZEMAX software to ensure that the ADC can work effectively at different zenith angles. - The complete optical path from the TMT focal plane to the spectrometer was designed, including components such as pick - off mirrors, collimators, RADC, and cameras. 3. **Performance Verification** - The performance improvement of the ADC after correcting atmospheric dispersion was verified through the calculation of Geometric Throughput (GT) and Signal - to - Noise Ratio (SNR). - The results show that after dispersion correction, the geometric throughput is increased by about 70%, and the signal - to - noise ratio is also significantly improved at high zenith angles. ### Summary The main purpose of this paper is to solve the atmospheric dispersion problem encountered in multi - object spectroscopic observations of large - aperture telescopes by designing an efficient atmospheric dispersion corrector, thereby improving the observation quality and efficiency. This design is not only applicable to TMT, but also provides a reference for similar applications of other large telescopes in the future. ### Formula Summary - Geometric Throughput (% GT) Calculation Formula: \[ \% \text{GT} = \left( \frac{\text{OPI}}{\text{IPI}} \right) \times 100 \] where: - \(\text{IPI}\): Input Intensity (before correction) - \(\text{OPI}\): Output Intensity (after correction) - Signal - to - Noise Ratio (SNR) Calculation Formula: \[ \text{SNR/Pixel} = \sqrt{\left( \frac{N}{R \times \text{PSFwidth}} \right) \times SR} \] where: - \(N\): Number of photons per square centimeter per second - \(R\): Spectral Resolution - \(\text{PSFwidth}\): Point Spread Function Width - \(SR\): Total System Response \[ SR = A \times r(\lambda) \times t(\lambda) \times t_f(\lambda) \times \% \text{GT}(\text{zenith}) \times \eta \times \text{QE} \] where: - \(A\): Collection Area - \(r(\lambda)\): Reflectivity - \(t(\lambda)\)