Performance in beam tests of Carbon-enriched irradiated Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector

S. Ali,H. Arnold,S. L. Auwens,L. A. Beresford,D. E. Boumediene,A. M. Burger,L. Cadamuro,L. Castillo García,L. D. Corpe,M. J. Da Cunha Sargedas de Sousa,D. Dannheim,V. Dao,A. Gabrielli,Y. El Ghazali,H. El Jarrari,V. Gautam,S. Grinstein,J. Guimarães da Costa,S. Guindon,X. Jia,G. Kramberger,Y. Liu,K. Ma,N. Makovec,S. Manzoni,I. Nikolic,O. Perrin,V. Raskina,M. Robles Manzano,A. Rummler,Y. Tayalati,S. Trincaz-Duvoid,A. Visibile,S. Xin,L. Xu,X. Yang,X. Zheng
DOI: https://doi.org/10.1088/1748-0221/18/05/P05005
2023-03-17
Abstract:The High Granularity Timing Detector (HGTD) will be installed in the ATLAS experiment to mitigate pile-up effects during the High Luminosity (HL) phase of the Large Hadron Collider (LHC) at CERN. Low Gain Avalanche Detectors (LGADs) will provide high-precision measurements of the time of arrival of particles at the HGTD, improving the particle-vertex assignment. To cope with the high-radiation environment, LGADs have been optimized by adding carbon in the gain layer, thus reducing the acceptor removal rate after irradiation. Performances of several carbon-enriched LGAD sensors from different vendors, and irradiated with high fluences of 1.5 and 2.5 x 10^15 neq/cm2, have been measured in beam test campaigns during the years 2021 and 2022 at CERN SPS and DESY. This paper presents the results obtained with data recorded by an oscilloscope synchronized with a beam telescope which provides particle position information within a resolution of a few um. Collected charge, time resolution and hit efficiency measurements are presented. In addition, the efficiency uniformity is also studied as a function of the position of the incident particle inside the sensor pad.
Instrumentation and Detectors,High Energy Physics - Experiment
What problem does this paper attempt to address?
The paper attempts to address the issue of optimizing the performance of Low Gain Avalanche Detectors (LGAD) in the high-radiation environment of the High-Luminosity Large Hadron Collider (HL-LHC) to meet the requirements of the High Granularity Timing Detector (HGTD) in the ATLAS experiment. Specifically, the study aims to evaluate the performance of LGAD sensors with added carbon elements under different irradiation levels, focusing on key parameters such as collected charge, time resolution, and hit reconstruction efficiency. ### Background and Objectives - **Background**: The ATLAS experiment plans to install a High Granularity Timing Detector (HGTD) during the HL-LHC phase to mitigate the effects of particle pile-up during collisions. LGAD sensors, known for their high-precision time measurement capabilities, have been selected as a key component of the HGTD. - **Objectives**: To optimize LGAD sensors so that they maintain high performance in high-radiation environments. Specific requirements include: - Time resolution of 50 picoseconds (70 picoseconds) per hit. - Collected charge greater than 4 femtocoulombs. - Hit efficiency of 97% at the beginning of life and 95% at the end of life. ### Main Content - **Sensor Optimization**: By adding carbon elements to the gain layer, the acceptor removal rate after irradiation is reduced, thereby enhancing the radiation hardness of the sensors. - **Testing Methods**: Performance tests of carbon-enriched LGAD sensors produced by different manufacturers were conducted using beam test facilities. The tests included measurements of collected charge, time resolution, and hit reconstruction efficiency. - **Results Analysis**: Data analysis was performed to evaluate the performance of the sensors under different irradiation levels and to compare the advantages and disadvantages of sensors produced by different manufacturers. ### Conclusion - **Performance Evaluation**: The results show that at irradiation levels of 1.5 and 2.5 × 10^15 n_eq/cm², LGAD sensors with added carbon elements exhibit good performance in terms of collected charge, time resolution, and hit reconstruction efficiency. - **Optimization Recommendations**: Some sensors maintain high performance even at high irradiation levels, with sensors produced by IHEP performing particularly well at an irradiation level of 2.5 × 10^15 n_eq/cm². ### Significance - **Technological Advancement**: This study provides important references for the design and optimization of sensors in high-radiation environments, contributing to improved detector performance in future high-energy physics experiments. - **Application Prospects**: Optimized LGAD sensors are expected to play a significant role in future high-luminosity collider experiments, enhancing the accuracy and efficiency of data collection.