Charge-sensitive front-end electronics with operational amplifiers for CdZnTe detectors

P. Födisch,M. Berthel,B. Lange,T. Kirschke,W. Enghardt,P. Kaever
DOI: https://doi.org/10.1088/1748-0221/11/09/T09001
2016-08-19
Abstract:Cadmium zinc telluride (CdZnTe, CZT) radiation detectors are suitable for a variety of applications, due to their high spatial resolution and spectroscopic energy performance at room temperature. However, state-of-the-art detector systems require high-performance readout electronics. Though an application-specific integrated circuit (ASIC) is an adequate solution for the readout, requirements of high dynamic range and high throughput are not available in any commercial circuit. Consequently, the present study develops the analog front-end electronics with operational amplifiers for an 8x8 pixelated CZT detector. For this purpose, we modeled an electrical equivalent circuit of the CZT detector with the associated charge-sensitive amplifier (CSA). Based on a detailed network analysis, the circuit design is completed by numerical values for various features such as ballistic deficit, charge-to-voltage gain, rise time, and noise level. A verification of the performance is carried out by synthetic detector signals and a pixel detector. The experimental results with the pixel detector assembly and a 22Na radioactive source emphasize the depth dependence of the measured energy. After pulse processing with depth correction based on the fit of the weighting potential, the energy resolution is 2.2% (FWHM) for the 511 keV photopeak.
Instrumentation and Detectors
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to design a high - performance front - end electronic read - out system suitable for CdZnTe (CZT) detectors in high - energy gamma - ray detection. Specifically, the existing application - specific integrated circuits (ASICs) have limitations in handling high - dynamic - range and high - throughput data and cannot meet the requirements of proton therapy imaging systems. Therefore, this paper proposes an analog front - end electronic system based on commercial operational amplifiers, aiming to overcome these limitations and achieve efficient reading and processing of CZT detector signals. ### Main Objectives 1. **Improve Dynamic Range**: CZT detectors need to be able to detect low - energy scattering events while being exposed to high - energy gamma - rays, which places high demands on the dynamic range of the read - out system. 2. **Retain Time Information**: Traditional ASICs usually only include simple analog signal processing, such as leading - edge triggering and peak - holding circuits, which makes pulse - shape analysis and advanced timing difficult or impossible. The new front - end electronic system needs to be able to preserve the time information of the interaction. 3. **Adapt to High Energy and High Counting Rates**: Proton therapy imaging systems need to handle energies up to 7 MeV and counting rates up to 1 Mcps, and existing ASICs cannot meet these requirements. ### Solutions - **Use Commercial Operational Amplifiers**: By using commercial operational amplifiers to build the front - end electronic system, the limitations of ASICs can be avoided, while taking advantage of the reliability and life - cycle support of off - the - shelf components. - **Optimize Circuit Design**: Through detailed analysis of the design of the charge - sensitive pre - amplifier (CSA), key parameters such as ballistic deficit, charge - to - voltage gain, rise time, and noise level are determined. - **Verify Performance**: Experimental verification is carried out through synthetic detection signals and pixel detectors. The results show that after depth correction, the energy resolution of the 511 - keV photopeak is 2.2% (FWHM). ### Key Technical Points - **Charge - Sensitive Pre - amplifier (CSA)**: By adding a capacitor to the feedback loop of the operational amplifier, charge - to - voltage conversion is achieved, thereby obtaining a voltage output proportional to the moving charge. - **Ballistic Deficit**: By adjusting the feedback time constant, the performance of the CSA is optimized, and the influence of ballistic deficit on the signal is reduced. - **Noise Control**: By selecting appropriate component values and circuit layouts, the noise level is reduced and the signal quality is improved. In conclusion, through the design and optimization of the front - end electronic system based on commercial operational amplifiers, this paper solves the deficiencies of existing ASICs in high - dynamic - range and high - throughput data processing, and provides an effective solution for the application of CZT detectors in proton therapy imaging systems.