Experimental study on a dry dilution refrigerator driven by a high-power linear compressor

Maowen Zheng,Jianguo Li,Haowen Guo,Lingjiao Wei,Zijie Pan,Ruixin Li,Houlei Chen,Jingtao Liang
DOI: https://doi.org/10.1016/j.cryogenics.2024.103802
IF: 2.134
2024-02-09
Cryogenics
Abstract:With the development of quantum computing and other fields, dilution refrigerators are required to have greater cooling capacity. More cooling power means larger 3 He flow rate and the corresponding gas circulation system. In dry dilution refrigerators, 3 He needs to be pressurized by compressor for the high inlet pressure. This paper introduces a dry dilution refrigerator driven by a designed high-power two-stage linear compressor, and the reliability of the compressor is verified by experiments. 3 He can be pressurized to a pressure above 200 kPa at a flow rate of nearly 1 mmol/s and be condensed successfully in the condensatiion process. The refrigerator, precooled by a pulse tube cryocooler, can obtain a minimum temperature of 19 mK and a cooling capacity of 250 μW at about 100 mK at the total flow rate of about 0.45 mmol/s. The maximum power of 3 He compressor can reach 300 W and the maximum compression ratio is over 10, which can be used as the 3 He driver of high-power dilution refrigerators or closed-cycle space dilution refrigerators.
thermodynamics,physics, applied
What problem does this paper attempt to address?