A Novel Oscillation Wave Test System for Partial Discharge Detection in XLPE Cable Lines

Guangya Zhu,Kai Zhou,Shilin Zhao,Yuan Li,Lu Lu
DOI: https://doi.org/10.1109/tpwrd.2019.2949843
IF: 4.825
2020-08-01
IEEE Transactions on Power Delivery
Abstract:This paper presents a novel oscillation wave test system (OWTS) to detect the partial discharge (PD) of mounting defects in power cable insulation. In the proposed system, a charging capacitor is added to the circuit topology based on the traditional OWTS. The charging capacitor is charged to the desired voltage by a high-voltage DC power source. After the charging process, the test cable sample is charged by the capacitor. The resonant circuit is formed by the charging capacitor, the test cable, and the resonant reactor to create an oscillating decay voltage. With this novel method, no space charge is injected into the cable insulation. The effect of the charging capacitance on the charging efficiency is calculated with the Multisim software. This paper describes the working principle and the assembly of a laboratory prototype for the PD detection of a 500 m cable circuit. The test results show the feasibility of the novel OWTS method.
engineering, electrical & electronic
What problem does this paper attempt to address?