Detection Method Of Partial Discharge In Xlpe Cable Accessories Based On The Method Of Vhf Combined With Acoustic Emission

Wei Wang,Xu Cheng,Chong Liu,Fei Zong,XueLiang Shen
DOI: https://doi.org/10.1109/ISEIM.2008.4664589
2008-01-01
Abstract:In this paper, the method of VHF Combined with acoustic emission (AE) for detecting PD in the XLPE cable accessories was introduced. There are several advantages using this method. Such as: It can resist the electromagnetic interference effectively and locate the defect definitely as well as can calibrate the apparent discharge magnitude. Based on the experiment, the relationships were researched between the VHF and acoustic emission PD signals. Two kinds PD spectrum of Qmax-phi and N-phi were analyzed and contrasted between the VHF and acoustic emission PD signals, which are protrusion discharge and floating discharge. The results of the research had proved that the reliability of the PD detection is improved using the combined method.
What problem does this paper attempt to address?