Thermal Stability and Corrosion Resistance in Liquid Lithium of Brazed Tungsten Smart Alloy/RAFM Steel Joints

Kirillova, V. O.
DOI: https://doi.org/10.1007/s10894-024-00472-1
IF: 1.793
2024-12-12
Journal of Fusion Energy
Abstract:Oxidation resistant smart tungsten alloys (SA) are considered a promising plasma facing material for DEMO reactors. SA-based plasma facing components (PFC) have to meet several long-term operation requirements. Among other criteria, these PFC should be able to withstand high thermal loads and be corrosion resistant in liquid lithium for a liquid first wall design implementation. In this work, smart tungsten alloys WCrY, WCrZr were brazed to reduced activation ferritic-martensitic (RAFM) steels Eurofer97, CLAM via 48Ti–48Zr–4Be wt.% brazing alloy. Thermal stability of the brazed joints was investigated. High temperature shear tests at 300, 600 °C were carried out. The shear strength of WCrZr/Ta/CLAM joints is 50 ± 4 and 49 ± 5 MPa at 300 and 600 °C, respectively. Unbrazing of the WCrY/Ta/Eurofer97 and WCrZr/Ta/CLAM joints occurs at 1447 and 1522 °C, respectively, due to the melting of steels. Corrosion resistance of the smart tungsten alloys, SA/Ta/RAFM joints in liquid lithium at 600 °C, 100 h exposure was demonstrated.
nuclear science & technology