Evaluation of Lateral Radar Positioning for Vital Sign Monitoring: An Empirical Study

Lars Hornig,Benedek Szmola,Wiebke Pätzold,Jan Paul Vox,Karen Insa Wolf
DOI: https://doi.org/10.3390/s24113548
IF: 3.9
2024-05-31
Sensors
Abstract:Vital sign monitoring is dominated by precise but costly contact-based sensors. Contactless devices such as radars provide a promising alternative. In this article, the effects of lateral radar positions on breathing and heartbeat extraction are evaluated based on a sleep study. A lateral radar position is a radar placement from which multiple human body zones are mapped onto different radar range sections. These body zones can be used to extract breathing and heartbeat motions independently from one another via these different range sections. Radars were positioned above the bed as a conventional approach and on a bedside table as well as at the foot end of the bed as lateral positions. These positions were evaluated based on six nights of sleep collected from healthy volunteers with polysomnography (PSG) as a reference system. For breathing extraction, comparable results were observed for all three radar positions. For heartbeat extraction, a higher level of agreement between the radar foot end position and the PSG was found. An example of the distinction between thoracic and abdominal breathing using a lateral radar position is shown. Lateral radar positions could lead to a more detailed analysis of movements along the body, with the potential for diagnostic applications.
engineering, electrical & electronic,instruments & instrumentation,chemistry, analytical
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is: in vital sign monitoring, how to improve the accuracy of respiration and heartbeat signal extraction through lateral radar positioning, especially in the application scenario of sleep monitoring. Specifically, the paper explores the influence of different radar placement positions on the extraction effect of respiration and heartbeat signals, aiming to find a more effective method to separate respiratory movement and heartbeat pulse, thereby avoiding the problem of respiratory movement masking the heartbeat signal. ### Detailed Explanation 1. **Existing Problems**: - Current vital sign monitoring mainly relies on contact - type sensors. Although these sensors are accurate, they are costly and inconvenient to use. - Non - contact - type sensors such as radar offer a promising alternative, but face some challenges in practical applications, such as the problem of respiratory movement masking the heartbeat signal. 2. **Research Objectives**: - Evaluate the influence of lateral radar positioning on the extraction of respiration and heartbeat signals. - Explore whether lateral radar positioning can better separate respiratory movement and heartbeat pulse, thereby improving the detection accuracy of the heartbeat signal. 3. **Research Methods**: - Through a sleep experiment, place the radar at different positions on the bed (top, bedside table, foot of the bed), and compare it with polysomnography (PSG) as a reference system. - Analyze the effect of different radar positions on the extraction of respiration and heartbeat signals. The quantitative indicators include vital sign detection rate, time reliability, and calculated vital sign accuracy. 4. **Expected Results**: - For respiration signal extraction, the performance of all three radar positions should be similar. - For heartbeat signal extraction, the radar at the foot of the bed should show higher consistency with PSG, because this position can better separate respiration and heartbeat signals. ### Formula Explanation The formulas involved in the paper are mainly used to explain the working principle of FMCW radar and its processing of vital sign signals: - **Distance Calculation Formula**: \[ d=\frac{f_d c}{2S} \] where \(d\) is the distance of a static reflecting object, \(f_d\) is the frequency difference between the received wave and the transmitted wave, \(c\) is the speed of light, and \(S\) is the rate of frequency increase over time. - **Range Shell Depth Formula**: \[ d_{\text{shell}}=\frac{c}{2B} \] where \(B\) is the sweep - frequency bandwidth. For commercial radars, when the bandwidth is 3 GHz, the shell depth is approximately 5 cm. - **Phase Expression**: \[ \varphi=\frac{4\pi f_{\min}R}{c} \] where \(f_{\min}\) is the minimum frequency of the FMCW radar, \(R\) is the displacement, and \(c\) is the speed of light. Through these formulas, the radar can detect the tiny respiratory and heartbeat movements of the human body with high precision and convert them into available vital sign data.