Systematic Literature Review Regarding Heart Rate and Respiratory Rate Measurement by Means of Radar Technology

Magdalena Liebetruth,Kai Kehe,Dirk Steinritz,Stefan Sammito
DOI: https://doi.org/10.3390/s24031003
IF: 3.9
2024-02-05
Sensors
Abstract:The use of radar technology for non-contact measurement of vital parameters is increasingly being examined in scientific studies. Based on a systematic literature search in the PubMed, German National Library, Austrian Library Network (Union Catalog), Swiss National Library and Common Library Network databases, the accuracy of heart rate and/or respiratory rate measurements by means of radar technology was analyzed. In 37% of the included studies on the measurement of the respiratory rate and in 48% of those on the measurement of the heart rate, the maximum deviation was 5%. For a tolerated deviation of 10%, the corresponding percentages were 85% and 87%, respectively. However, the quantitative comparability of the results available in the current literature is very limited due to a variety of variables. The elimination of the problem of confounding variables and the continuation of the tendency to focus on the algorithm applied will continue to constitute a central topic of radar-based vital parameter measurement. Promising fields of application of research can be found in particular in areas that require non-contact measurements. This includes infection events, emergency medicine, disaster situations and major catastrophic incidents.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
This paper aims to systematically review the research on non - contact heart rate and respiratory rate measurement using radar technology. Specifically, the paper analyzes the accuracy of using radar technology to measure heart rate and/or respiratory rate through a systematic literature search. The main objectives of the study include: 1. **Evaluating the accuracy of radar technology in non - contact measurement of heart rate and respiratory rate**: The paper analyzes the maximum deviation of using radar technology to measure heart rate and respiratory rate in different studies. The results show that in the studies of measuring respiratory rate, 37% of the maximum deviation is 5%, while in the studies of measuring heart rate, 48% of the maximum deviation is 5%. For a tolerance deviation of 10%, the corresponding percentages are 85% and 87% respectively. 2. **Exploring the factors affecting the measurement results**: The paper points out that the quantitative comparison in the current literature is affected by multiple variables, including radar type, measurement distance, position and posture of the test object, etc. Therefore, eliminating the influence of these confounding variables and continuing to focus on the improvement of the applied algorithms will be the focus of future research. 3. **Exploring the application potential of radar technology in specific fields**: The paper specifically mentions the application prospects in fields requiring non - contact measurement, such as infectious events, emergency medicine, disaster situations and major disaster accidents. In conclusion, through a systematic review of existing research, this paper aims to clarify the current situation of radar technology in non - contact measurement of heart rate and respiratory rate and propose the direction for future research.