Vital-sign monitoring and spatial tracking of multiple people using a contactless radar-based sensor

Marco Mercuri,Ilde Rosa Lorato,Yao-Hong Liu,Fokko Wieringa,Chris Van Hoof,Tom Torfs
DOI: https://doi.org/10.1038/s41928-019-0258-6
IF: 33.255
2019-06-01
Nature Electronics
Abstract:Various medical systems exist for monitoring people in daily life, but they typically require the patient to wear a device, which can create discomfort and can limit long-term use. Contactless vital-sign monitoring would be preferable, but such technology is challenging to develop as it involves weak signals that need to be accurately detected within a practical distance, while being reliably distinguished from unwanted disturbance. Here, we show that a radar-based sensor can be used to monitor the individual vital signs (heartbeat and respiration) of multiple people in a real-world setting. The contactless approach, which does not require any body parts to be worn, uses two antennas (one transmitter and one receiver) and algorithms for target tracking and rejection of random body movements. As a result, it is robust against moderate random body movements (limb movements and desk work) and can keep track of individual people during vigorous movement (such as walking and standing up).
engineering, electrical & electronic
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: in the real - world environment, to achieve the monitoring of vital signs (such as heartbeat and respiration) of multiple individuals and spatial tracking through non - contact radar sensors. Specifically, this technology aims to overcome the limitations of existing methods, such as the need to wear devices, being able to work only under ideal conditions (such as relatively stationary human bodies), difficulty in dealing with random body movements, and interference from static clutter reflections in indoor environments. ### Main Objectives of the Paper 1. **Non - contact Multi - human Vital Sign Monitoring**: Develop a radar system that does not require any wearable devices and can simultaneously monitor the vital signs of multiple individuals in a real environment. 2. **Coping with Random Body Movements**: Design algorithms to handle moderate random body movements (such as limb activities and work at a desk) to ensure the accuracy of vital sign data. 3. **Robustness in Complex Environments**: Ensure that the system can still work effectively in indoor environments with a large number of static reflectors (such as furniture, metal objects, etc.). 4. **Multi - target Tracking**: Achieve spatial tracking of multiple moving targets and be able to distinguish the movements and vital signs of different individuals. ### Solutions To achieve the above objectives, the authors propose the following key technologies: - **Dual - antenna FMCW Radar Architecture**: Use one transmitting antenna and one receiving antenna, based on the linear frequency - modulated continuous - wave (FMCW) radar technology. - **Target Tracking Algorithm**: Combine speed and distance information, and track multiple targets through the Doppler effect and phase information. - **Random Body Movement Suppression Algorithm**: Utilize the continuous wavelet transform (CWT) and the sliding - window processing method to identify and suppress artifacts caused by random body movements. - **Linear Demodulation and Wave Decomposition**: Extract the phase information of the Doppler signal through linear demodulation, and use the discrete Meyer wavelet to separate the respiration and heart rate components. ### Experimental Verification The authors conducted multiple experiments in laboratory and simulated office environments to verify the performance of the system. The results show that the system has a high success rate (more than 95%) in target detection and clutter suppression, and can accurately monitor the human vital signs in both stationary and moving states. ### Formula Summary 1. **Calculation of Maximum Doppler Velocity**: \[ v_{\text{max}}=\frac{\lambda_0 f_d}{2} \] where \(\lambda_0 = \frac{c}{f_0}\) is the wavelength corresponding to the initial frequency \(f_0\), and \(f_d\) is the Doppler frequency. 2. **Calculation of FFT Size**: \[ N = 2^{\lceil\log_2\left(\frac{v_{\text{max}}}{\Delta v}\right)\rceil} \] where \(\Delta v\) is the speed resolution. 3. **Calculation of Doppler Phase Shift**: \[ \phi(t)=\frac{4\pi f_0 x(t)}{c} \] where \(x(t)\) is the vibration displacement of the thoracic surface. 4. **Doppler Signal Processing after Random Movement Suppression**: Use the sliding window and the discrete Meyer wavelet to separate the respiration and heart rate components, and evaluate the spectral peak frequency through FFT. Through these methods, this paper proposes an innovative non - contact radar system that can achieve the monitoring of vital signs and spatial tracking of multiple people in complex environments, providing new solutions for elderly care and telemedicine.