Pi-ViMo: Physiology-inspired Robust Vital Sign Monitoring using mmWave Radars

Bo Zhang,Boyu Jiang,Rong Zheng,Xiaoping Zhang,Jun Li,Qiang Xu
2023-03-24
Abstract:Continuous monitoring of human vital signs using non-contact mmWave radars is attractive due to their ability to penetrate garments and operate under different lighting conditions. Unfortunately, most prior research requires subjects to stay at a fixed distance from radar sensors and to remain still during monitoring. These restrictions limit the applications of radar vital sign monitoring in real life scenarios. In this paper, we address these limitations and present "Pi-ViMo", a non-contact Physiology-inspired Robust Vital Sign Monitoring system, using mmWave radars. We first derive a multi-scattering point model for the human body, and introduce a coherent combining of multiple scatterings to enhance the quality of estimated chest-wall movements. It enables vital sign estimations of subjects at any location in a radar's field of view. We then propose a template matching method to extract human vital signs by adopting physical models of respiration and cardiac activities. The proposed method is capable to separate respiration and heartbeat in the presence of micro-level random body movements (RBM) when a subject is at any location within the field of view of a radar. Experiments in a radar testbed show average respiration rate errors of 6% and heart rate errors of 11.9% for the stationary subjects and average errors of 13.5% for respiration rate and 13.6% for heart rate for subjects under different RBMs.
Signal Processing,Human-Computer Interaction
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the limitations of existing millimeter - wave radar in monitoring human vital signs. Specifically, most previous studies require the monitored object to remain at a fixed distance and must be stationary during the monitoring process. These limitations greatly restrict the application of radar vital - sign monitoring in real - world scenarios. Therefore, this paper proposes a new non - contact, physiology - inspired robust vital - sign monitoring system - Pi - ViMo (Physiology - inspired Robust Vital Sign Monitoring), aiming to overcome these limitations. ### Main Problems 1. **Fixed - Distance and Stationary Requirements**: Existing methods usually require the tested person to remain at a fixed distance and be stationary, which is difficult to achieve in practical application scenarios. 2. **Multi - Scattering - Point Model and Coherent Combination**: Traditional methods assume that the human chest is a single scattering point, ignoring the multi - scattering characteristics of the human chest at close range, resulting in large estimation errors. 3. **Micro - Motion Interference**: Even under small - amplitude involuntary body movements (such as slight shaking), existing methods have difficulty accurately separating the respiration and heartbeat signals. ### Solutions 1. **Multi - Scattering - Point Model (MSP)**: A multi - scattering - point model is introduced to describe the radar reflection signals of the human chest, and the accuracy of displacement estimation is improved by considering multiple scattering points. 2. **Coherent Combination (CC)**: A coherent combination algorithm is proposed to add signals from multiple range cells to enhance the estimated quality of chest - wall movement. 3. **Template Matching (TM)**: A physical model is used to model respiration and cardiac activities, and an optimization method based on template matching is proposed to extract vital - sign signals, thus effectively separating the respiration and heartbeat signals and maintaining high accuracy even in the presence of micro - motion interference. ### Experimental Results The experimental results show that under static conditions, the average error of the respiration rate of the Pi - ViMo system is 6% and the average error of the heart rate is 11%; under different micro - motion conditions, the average errors of the respiration rate and the heart rate are 12% and 13% respectively. These results indicate that the Pi - ViMo system can effectively monitor vital signs under different distances and micro - motion conditions, significantly outperforming the existing baseline methods. In conclusion, this paper solves the key problems in existing millimeter - wave radar vital - sign monitoring by introducing the multi - scattering - point model and the coherent combination technique, making non - contact vital - sign monitoring more suitable for practical application scenarios.