Study on Coupled Vibration of Human-plate System under Pedestrian Excitation

Lilin Cao,Niankang Wang,Chunhua Lu,Manicka Dhanasekar
DOI: https://doi.org/10.1007/s12205-024-1446-0
IF: 2.115
2024-01-19
KSCE Journal of Civil Engineering
Abstract:In the paper, in order to explore the influence of human-structure interaction (HSI) in the vertical direction on the dynamic response of floors due to human-induced excitation, the formula for the human-plate interaction system is deduced. The pedestrian is in turn modelled as moving force (MF), spring-mass-damper (SMD), and added mass-spring-mass-damper (MSMD). The floor is modelled using a formulation in modal coordinates. Aiming at the formula of human-plate interaction system, the state space method is used to get the instantaneous frequency and instantaneous damping ratio of the floor under walking excitation, and the acceleration responses can be obtained using the Runge-Kutta method. Furthermore, this work studies the influence of pedestrian mass and structural modal mass on structural vibration response. The results show that the floor frequency is observed to decrease and the damping ratio gives the opposite trend when the pedestrian enters the floor. The MF model overestimates the measured response, while the actual results can be well approximated by the results for SMD and MSMD models considering HIS. Accounting for increasing human mass and decreasing modal mass lead to significant increase in the dynamic properties and the structural response.
engineering, civil
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the influence of the coupled vibration of the human - slab system on the structural response under pedestrian excitation. Specifically, the research aims to evaluate the influence of the human - structure interaction (HSI) in the vertical direction caused by pedestrians walking on the floor slab on the dynamic response of the floor slab through three different pedestrian models (Moving Force model MF, Spring - Mass - Damper model SMD, and Added - Mass - Spring - Mass - Damper model MSMD). In addition, the research also explores the influence of the mass of pedestrians and the structural modal mass on the structural vibration response. ### Research Background With the application of high - strength and lightweight materials in the construction industry, modern structural design tends to be large - span building design, which makes the structure more vulnerable to the vibration caused by pedestrians. Therefore, accurately evaluating the structural response is a crucial step to ensure that the building meets the standards. Pedestrians not only generate loads on the structure but also have dynamic interactions with the structure, a phenomenon known as human - structure interaction (HSI). In recent years, research on HSI has gradually increased, but it is still challenging to establish a model that comprehensively considers various factors. ### Research Methods 1. **Model Selection**: - **Moving Force model (MF)**: Simplify the pedestrian as a moving force that crosses the floor slab at a constant speed. - **Spring - Mass - Damper model (SMD)**: Consider the mass, damping, and stiffness of the pedestrian. - **Added - Mass - Spring - Mass - Damper model (MSMD)**: Further consider the added mass of the pedestrian. 2. **Floor Slab Modeling**: - The floor slab is simplified as an orthotropic plate and modeled using modal coordinates. 3. **Dynamics Equations**: - Derive the formulas of the human - slab interaction system and use the state - space method to solve the instantaneous frequency and instantaneous damping ratio. - Use the Runge - Kutta method to obtain the acceleration response. ### Main Findings - **Changes in Frequency and Damping Ratio**: - When the pedestrian enters the floor slab, the frequency of the floor slab decreases while the damping ratio increases. - The Moving Force model (MF) overestimates the actually measured response, while the SMD and MSMD models can more accurately reflect the actual results. - **Influence of Pedestrian Mass and Modal Mass**: - Increasing the pedestrian mass and decreasing the modal mass will lead to a significant increase in dynamic characteristics and structural response. ### Example Application The paper verifies the effectiveness of the model through a specific example. The floor slab has a size of 9.144 m × 9.144 m, a thickness of 0.222 m, a natural frequency of 4.98 Hz, a density of 2322.9 kg/m³, and a modal damping ratio of 0.01. The total mass of the pedestrian is 80 kg, and the step frequencies are 1.66 Hz and 1.73 Hz respectively. The results show that the predicted values of the SMD and MSMD models are very close to the actually measured values, while the MF model significantly overestimates the response. ### Conclusion This research proves the importance of considering human - structure interaction by comparing the influence of different pedestrian models on the dynamic response of the floor slab. The SMD and MSMD models are more accurate in predicting the structural response, especially in the case of changes in pedestrian mass and modal mass. These findings are of great significance for designing and evaluating the vibration performance of modern large - span structures.